[Buildroot] [PATCH v2 3/3] package/modem-manager: bump version to 1.20.2

Thomas Petazzoni thomas.petazzoni at bootlin.com
Mon Dec 12 09:29:49 UTC 2022


On Mon, 12 Dec 2022 10:19:32 +0100
Aleksander Morgado <aleksander at aleksander.es> wrote:

> The build-time dependency on DBus is exclusively to read
> "interfaces_dir" and "system_bus_services_dir" from the pkg-config
> (/usr/lib/pkgconfig/dbus-1.pc) file installed. I agree this is not
> very pretty, as we don´t really require a full working DBus, just the
> pkgconfig file :/

ACK!

> No, udevdir is required even if -Dudev=false. The reason is that
> udevdir is used to install the udev rules files, and ModemManager has
> a built-in udev rules parser used when the daemon is built without
> udev support (e.g. default in openwrt). The udev rules specify port
> type hints and other things, MM won't work fine without those rules.

OK, thanks for the information.

Heiko: will you follow-up with an updated patch?

Thanks!

Thomas
-- 
Thomas Petazzoni, co-owner and CEO, Bootlin
Embedded Linux and Kernel engineering and training
https://bootlin.com



More information about the buildroot mailing list